datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley 500 934 01C

Keithley 500 934 01C free download

Various electronics service manuals

File information:
File name:500_934_01C.pdf
[preview 500 934 01C]
Size:762 kB
Extension:pdf
Mfg:Keithley
Model:500 934 01C 🔎
Original:500 934 01C 🔎
Descr: Keithley 500 500_934_01C.pdf
Group:Electronics > Other
Uploaded:28-12-2019
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 500_934_01C.pdf

DlOl Digital Input/Output Module The DIOl Digital Input/Output Module 1 provides 32 programmable digital inputlout- put channels at LS-TTL levels. These channels are grouped into &bit ports, and each port can be individually programmed for input or output by on-card DIP switches. Rapid settling times allow sampling of high-speed digital inputs. Outputs are latched to allow asynchronous reading of the output data. I/O connections are made to on-card screw terminals, which accept 16-24 gage wire leads. In addition to the screw terminals, a jack is provided for quick connection and disconnection of inputs and outputs. The DIOl module can be installed in any available slot in the system; however, digital modules should generally be placed in the high-numbered slots if any analog modules are present in the system. To install the module, remove the baseboard top cover and insert the module into the desired slot with the component side facing the power supply. CAUTION: Always turn off the baseboard power before installling or removing modules. Replace the top cover and secure it with screws. To avoid the possibility of EM1 radiation, never operate the system with the top cover removed. User-Configured Components User-configured components for the DIOl include the input/ output connections and the I/O programming DIP switches, as listed in Table 1. Connections can be made either to screw terminals at the top of the module or to a separate on-card jack, which allow s the quick connection and disconnection of I/O lines. Input/output programming of each of the four ports is performed by setting DIP switches located on SlOl. for the location of these components, refer to Figure 1. Table 1. User-Configured Components Component Designation Function Screw Terminals J174 Input Output Signal Connections I/O Connector Pl.76 Quick Disconnect Signal Connections DIP Switches Slol Program Ports A-D for InnutlOutout Document Number: 500-934-01 Rev. C DIOl-1 GND +5v 0 1 2 Figure 1. DlOl Module Configuration Connections The screw terminals, which provide one means of making input/ output connections, are located on J174across the top edge of the module board. The channel numbers fo

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : epson MS-7529 v1.0

script execution: 0.03 s