datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley 27xxMaxSpeedBenchMark

Keithley 27xxMaxSpeedBenchMark free download

Various electronics service manuals

File information:
File name:27xxMaxSpeedBenchMark.pdf
[preview 27xxMaxSpeedBenchMark]
Size:184 kB
Extension:pdf
Mfg:Keithley
Model:27xxMaxSpeedBenchMark 🔎
Original:27xxMaxSpeedBenchMark 🔎
Descr: Keithley 2700 27xxMaxSpeedBenchMark.pdf
Group:Electronics > Other
Uploaded:24-01-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 27xxMaxSpeedBenchMark.pdf

Benchmarking the Reading Rate of an Integra Mainframe: Model 2700, 2701 or 2750 The DC Measurement Speeds specifications for the Integra mainframes are defined as the rate at which data can be acquired and put into a memory buffer. In order for your application to have this data for analysis, additional time is required to transfer the data across the bus (GPIB, RS- 232 or Ethernet). In order to verify the speed specification, analysis of the data returned when applying a signal of known frequency is required. If a 1 Hz waveform is applied and a buffer of data equal in size to the maximum rate is acquired, then the data in the buffer should represent 1 second or 1 full cycle of the applied waveform. Below is a screen shot from a LabVIEW program that performs this benchmark. This example, in LabVIEW 6i, is available in the download center of the Keithley web site as an example program for the Model 2700. It uses NI-VISA to send SCPI commands to the 2700 over GPIB. Figure 1: One Cycle of Applied Sine Wave As the Waveform Chart shows, one complete cycle of the applied sine wave has been acquired in the 2000 buffer points for the 2700. If using a 2750, adjust the buffer size to 2500 samples. If using a 2701, adjust the buffer size to 3500. Below are the SCPI commands used in the program: *RST;*CLS; Reset the instrument; clear status and errors TRAC:CLE Clear the buffer INIT:CONT OFF Disables continuous initiation (auto run) :SENSE:FUNCTION 'VOLT:DC' Measure DC volts :FORMAT:ELEM READ; Store only the reading in the buffer :SYSTEM:AZERO:STATE OFF Do not use auto zero :SENSE:VOLT:DC:AVERAGE:STATE OFF Disable filters :SENSE:VOLT:DC:NPLC 0.01 Set integration rate; 2701 has 0.002 available :SENSE:VOLT:DC:RANGE 10 Use a fixed range :SENSE:VOLT:DC:DIGITS 4.5 Set the reading resolution :TRIGGER:COUNT 1 Only one trigger required :SAMPLE:COUNT 2000 Change Sample Count according to your Model :TRIGGER:DELAY 0.0 Do not delay after trigger is issued :DISPLAY:ENABLE OFF Turn off the front panel display :READ? Issue software trigger

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Philips PHILIPS AUDIO service bulletins and tips

script execution: 0.04 s