MakeModelProblemSolutionDate
Found: 4551
PhilipsFL1.6shuts down with leds flashingerror code 99 (prot mode) C2523 8n2 2kv arcing (Check blue box caps)14-09-04
PhilipsFL1.6Shuts off sometimes no sync, dark picture, OSD on screen.Check if pulses on pin 25 of IC7120 (IC7220 in stocklist of service manual) on LFR box are present. If not present replace IC7120 (4822 209 31061; S87C652). 14-09-04

PhilipsFL1.6Shuts off sometimes no sync, dark picture, OSD on screen.Check if pulses on pin 25 of IC7120 (IC7220 in stocklist of service manual) on LFR box are present. If not present replace IC7120 (4822 209 31061; S87C652). 14-09-04
PhilipsFL1.6Small picture with flyback lines. The +141 is about 110V.Check D6372 on LSP (LL4148; 4822 130 80446). 14-09-04
PhilipsFL1.6Sometimes blue picture, no DC level on pin 7 of IC7430Check/replace IC7430 (TDA4680; 4822 209 31592). 14-09-04
PhilipsFL1.6Sometimes in protection, or hor. width variesCheck or resolder on LSP the pins of E/W bridge coil 5521. 14-09-04
PhilipsFL1.6Sometimes no synchronizationCheck diode 6007 on LFR (digital scan) box (4822 130 80888; BA682). REMARKS : Signal was 12MHz instead of 16MHz for 4:3 mode. 14-09-04
PhilipsFL1.6Sometimes no synchronizationCheck diode 6007 on LFR (digital scan) box (4822 130 80888; BA682). REMARKS : Signal was 12MHz instead of 16MHz for 4:3 mode. 14-09-04
PhilipsFL1.6Sometimes picture scrolls vertically.Check added circuit modification near TS7027 (Zener diode 5V6, diode 1N4148, resistor 1K). 14-09-04
PhilipsFL1.6Sometimes picture scrolls vertically.Check added circuit modification near TS7027 (Zener diode 5V6, diode 1N4148, resistor 1K). 14-09-04
PhilipsFL1.6Sometimes set shuts off and gives error 99.Offset voltage on protection line. Check D6376 (4822 130 81143; LLZ-C20) D6376 of the power supply on leakage. 14-09-04
PhilipsFL1.6Spoke on 134,25 and 287,25 MHz in proscan sets.Spoke on above mentioned frequency can be solved by adding two capacitors of 33pF (5322 122 32072) on the LFR box. - between pin 10 of H22 and earth (pin 5 of H22) (CVBS). - between pin 7 of H21 and earth (pin 4 of H21) (TXT INT). 14-09-04
PhilipsFL1.6Spook (interference and noise) in 100Hz sets1. Use special antenna cables: 4822 321 61224 PAL 1m 4822 321 61225 PAL 2m 4822 321 61226 SECAM 1m 4822 321 61227 SECAM 2m 2. Add 2 capacitors o14-09-04
PhilipsFL1.6Spook in pictureUse special antenna cables. Codenumbers: 4822 321 61224 PAL 1 meter 4822 321 61225 PAL 2 meter 4822 321 61226 SECAM 1 meter 4822 321 61227 SECAM 2 meter 14-09-04
PhilipsFL1.6Squeaking sound.Check C2520 (470 nF; 4822 121 51528). 14-09-04
PhilipsFL1.6Squeaking sound.Check C2520 (470 nF; 4822 121 51528). 14-09-04
PhilipsFL1.6Squeaking sound.Check C2520 (470 nF; 4822 121 51528). 14-09-04
PhilipsFL1.6Synchronization, picture disappearsD6703 and T7704 defective on picture tube panel. 14-09-04
PhilipsFL1.6The +141 is about 110V instead of 141VIt is recommended to replace the SOPS PWB (4822 310 31993). 14-09-04
PhilipsFL1.6Ticking noise and line in pictureTransistor 7381 (BC848C; 5322 130 42136) defective when hot. 14-09-04
PhilipsFL1.6Ticking sound left channel. Spikes on left channel.Check/replace Front-end item 1160 FQ816 ME/IF (4822 210 10409). 14-09-04
PhilipsFL1.6Total inoperative, leds blinking, error 99Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the Large signal panel. Replace by a 3kV15 HR-R capacitor if possible: 820pF 4822 126 13152 1nF 4822 126 13153 1,2nF 4822 126 13154 1,5nF 4822 126 13155 1,8nF 4822 126 13156 2,14-09-04

PhilipsFL1.6Total picture vibrates in vertical way, even on teletext.Check PLL signal on pin 26 of IC7219 on LFR box; if clock is 32.825 MHz; replace IC7120 (IC7220 in stocklist of service manual) (4822 209 31061; S87C652-SN40). 14-09-04
PhilipsFL1.6Total picture vibrates in vertical way, even on teletext.Check PLL signal on pin 26 of IC7219 on LFR box; if clock is 32.825 MHz; replace IC7120 (IC7220 in stocklist of service manual) (4822 209 31061; S87C652-SN40). 14-09-04
PhilipsFL1.6Totally inoperative, +5V is not present.Check IC7551 (4822 209 71825; LM358N). 14-09-04
PhilipsFL1.6Totally inoperative.Transistors 7250 (BUX85F; 4822 130 62509) and 7251 (BC848; 4822 130 61207) in microSOPS defective. Or D6251 (LLZ-C5V6; 4822 130 80954) and R1250 (=R3230; 1 Ohm; 4822 052 10108) defective. Or T7270 (BD825; 4822 130 41746) Or T7201 (BC857C; 5322 130 42714-09-04
PhilipsFL1.6Totally inoperative. Error code 9R3480 on SSP defect (4822 052 10278). 14-09-04
PhilipsFL1.6Tuning does not functionResistor R3240 on LSP in V-tuning wire broken. 14-09-04
PhilipsFL1.6Unsharp picture; VG2 varies with focus adjustmentReset pulse RSTN1 missing. IC7219 and IC7207 changed in LFR-box (4822 209 63892 and 4822 209 31056) 14-09-04
PhilipsFL1.6Unstable picture, horizontal jitter.Check/replace R3405 on the LSP. (4822 051 10303 for 50 Hz sets; 4822 051 10333 for 100 Hz sets). 14-09-04