datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....Login:
Pass:

[register] [send pass]
Bulgarian - schematics repairs service manuals English - schematics repairs service manuals Russian - schematics repairs service manualsSearchBrowseUploadMostWanted

Now downloading free:OLYMPUS C-3040 Zoom  [report bad file]  

Download OLYMPUS C-3040 Zoom docs - Cell phone, GSM, Satellite phone - Nokia, Siemens, Samsung mobiles service manuals and repair information

File information:
File name:OLYMPUS C-3040 Zoom.part1.rar
[preview C-3040 Zoom] new window
Size:2929 kB
Extension:
MD5 Checksum:e3c1fc95610afb21e98940a24bc2d7b7
Mfg:

OLYMPUS

Model:

C-3040 Zoom

Original Chassis:C-3040 Zoom
Descr:S.M.
Group:Electronics > GSM >
Uploaded:2010-05-30 08:30:25
User:kostake
Multipart: 0  1  2

Information about the files in archive:
Decompress result:OK
Extracted files:12
File nameText
1_Cover Page_v1.pdfREPAIR MANUAL C3040ZOOM - INDEX - SERVER_DIS Service Group, Technical Service Department OLYMPUS OPTICAL CO.,LTD Ver.1
B_Disassembly and Assembly Procedure_v1.pdfB. DISASSEMBLY AND ASSEMBLY PROCEDURE C-3040 Zoom B. DISASSEMBLY AND ASSEMBLY PROCEDURE REMOVAL OF CABINET TOP ASSEMBLY, CABINET FRONT ASSEMBLY AND CABINET BACK ASSEMBLY ... B-2 [2] REMOVAL OF LENS VF AND FLEXIBLE PWB ... B-3 [3] REMOVAL OF LENS ASSEMBLY AND CA1 BOARD ... B-4 [4] REMOVAL OF SY1 BOARD,CA2 BOARD AND ST1 BOARD ... B-4 [5] BOARD LOCATION ... B-5 [1] SERVER_DIS B-1 Ver.1 B. DISASSEMBLY AND ASSEMBLY PROCEDURE C-3040 Zoom [1]REMOVAL OF ABINET TOP ASSEMBLY,CABINET FRON TASSEMBLY AND CABINET BACK ASSEMBLY Disassembly perform as follows (1, 2...23) and assembly perform by reversing the disassembly steps (23, 22...1). Be sure to discharge the main capacitor in procedure 11, then continueu to disassembling. ! Beware of electric shock Danger of el
C_Adjustment Method_V1R3.pdfC. ADJUSTMENT METHOD C-3040 Zoom C. ADJUSTMENT METHOD [1] TABLE FOR SERVICING TOOLS ... C-2 [2] EQUIPMENT ... C-2 [3] ADJUSTMENT ITEMS AND ORDER ... C-2 [4] SETUP ... C-2 [5] CONNECTING THE CAMERA TO THE COMPUTER ... C-3 [6] USB STORAGE INFORMATION REGISTRATION ... C-4 [7] ADJUST SPECIFICATIONS ... C-5 1. IC501 OSCILLATION FREQUENCY ADJUSTMENT ... C-5 2. 5.1 V (A) VOLTAGE ADJUSTMENT ...
D_Repair Procedure_v1.pdfD. REPAIR PROCEDURE C-3040 Zoom D. REPAIR PROCEDURE [1] TROUBLESHOOTING GUIDE ... D-2 POWER LOSS INOPERATIVE ... D-2 TAKING INOPERATIVE ... D-2 NO PICTURE ... D-2 SERVER_DIS D-1 Ver.1 D. REPAIR PROCEDURE C-3040 Zoom [1] TROUBLESHOOTING GUIDE POWER LOSS INOPERTIVE IC301-91 (SCAN IN 0) PULSE INPUT TAKING INOPERATIVE PUSH SHUTTER BUTTON NO CHECK PFC include POWER SW, CN301, R3021 YES IC302-7 (UNREG) LOW CHECK ST1, CA2 IC301-3, 7 (SCAN IN 3) PULSE INPUT NO CHECK PFC include POWER SW, CN301, R3023, R3024 HIGH IC301-81 (VDD) YES LOW CHECK IC302 CN301-7, 8 (P ON, P(A) ON) LOW CHECK IC301, Q3005, Q3006, ST1 HIGH IC301-84 (RESET)
E_Notice of Modification_V1R6.pdfC-3040ZOOM E. NOTICE OF MODIFICATION 1. Correction of parts number ...E-2 2. Correction of parts number and description...E-3 E-1 Ver.1/Rev.6 E. NOTICE OF MODIFICATION C-3040ZOOM SUBJECT Correction of parts number 2002.12.6 [Content] Corrected the following parts number because of error in writing old GEAR CAM GEAR SHAFT VE083900 VE083955 new VE083901 VE083900 Rev.5 SERVER_DIS E-2 Ver.1 C-3040ZOOM SUBJECT Correction of parts number and description 2003.01.09 [Content] Corrected the following parts and description number because of error in writing old VJ1877000 4Z FRAME # new VJ187900 K-FPC# Rev.6 Ver.1 E-3
Maintenance History_V1R2.pdfMaintenance History MODEL: C-3040 Zoom No. Date of issued 2000.12.11 2000.01.10 Page Detail 1/1 Ver.1 Rev.1 1 set EPD:2/2 PL:2,6 Initial Revised Revised Revised Part number correction (VC153900VE297300) VE121500("NEW" Elimination),Serial number seal addition Part number correction (VJ140600VJ138100) Rev.2 2001.07.19 EPD:2/2 PL:3 SERVER_DIS Technical Service Group, Quality Assurance Department OLYMPUS OPTICAL CO.,LTD
Maintenance History_V1R6.pdfMaintenance History MODEL: C-3040 Zoom No. Date of issued 2000.12.11 2000.01.10 Page Detail 1/1 Ver.1 Rev.1 1 set EPD:2/2 PL:2,6 Initial Revised Revised Revised Part number correction (VC153900VE297300) VE121500("NEW" Elimination),Serial number seal addition Part number correction (VJ140600VJ138100) Rev.2 2001.07.19 EPD:2/2 PL:3 Rev.3 2002.10.07 C-1,12,13,14 EPD:3/3 PL:ALL(6) Addition Make the check procedure of Lens unit Add new parts of Lens unit Revised Revised Revised Corrected misprints Rev.4 Rev.5 2002.10.17 2002.12.06 EPD:1/3,2/3 E-1,2 EPD:2/3,3/3 PL:2/6 Correction of parts number Rev.6 2003.01.09 E-1,3 EPD: 3/3 PL:3/6 Revised Correction of parts number and description SERVER_DIS Technical Section, Support Service Department OLYMPUS OPTICAL CO., LTD
Parts List C-3040Zoom_V1R6.pdf A B C D Cabinet 1 VE208600 VC264500 VC266200 VE210000 1 VC264500 VC264500 VE210200 VE209200 VE087400 VE209800 VC266300 VE087800 VC130600 VC114700 VE202200 VC264500 VC129900 VE089300
T134-001.PDFNo. T134 - 001 27th Apr. 01 TECHNICAL INFORMATION OE/CPI-TSD C-3040ZOOM New Firmware (v354p-75) Description Changing the firmware of C-3040ZOOM because of improving software PAL : v354p-75 NTSC(GUI:English) : v354u-76 NTSC(GUI:Japanese) : v354-76 Contents The following contents are modified by new software. 1. It hangs-up, if folder name is "DCIM". Countermeasure Install the above new firmware in all C-3040ZOOM that has old firmware version. Version Up Procedure (From Smartmedia Card) 1. 2. 3. 4. 5. 6. 7. Prepare Smartmedia Card for new firmware Make "Firmware" folder in the Smartmedia Card Put new firmware as file name "firmware.bin" in "Firmware" folder. Note! : The file name has to be "firmware.bin", not "v354p-75". Insert the Smartmedia Card in C-3040ZOOM. Select "Play" mode with mode dial. Power ON C-3040ZOOM The current F/W version is indicated on TFT. Select "YES" and Press "OK" button. F/W rewriting is started automatically. It takes about 2 minutes. Note! : Don't touch an
T134-002.PDFNo. T134 - 002 30th Apr. 01 TECHNICAL INFORMATION OE/CPI-TSD Countermeasure for Record Error when "Red-Eye Reduction Flash" Mode is being used Model C-3000ZOOM / C-3030ZOOM / C-3040ZOOM / C-2040ZOOM Phenomenon Record error occurs when recording a picture which was taken with "Red-Eye Reduction Flash" mode, and it hangs-up. (This problem occurs seldom.) Cause Noise comes from a "CABINET TOP COVER" when flash is fired. Countermeasure Attach a Spacer Holder, if customer points out this problem. Please refer to the following picture. VC157400 SPACER HOLDER Spare parts number and name VC157400 : SPACER HOLDER OLYMPUS OPTICAL CO. (EUROPA) GMBH TECHNICAL SUPPORT DEPARTMENT CONSUMER PRODUCTS INTERNATIONAL 1/1
TID-C3040Z-E002.PDF TECHNICAL INFORMATION NO. TID-C3040Z-E002 DATE July/26/2001 SUBJECT: Matter of the part number change (finder) Content: There was an error in the part number (finder) of the following model. The part number is changed. Product name: C-3040ZOOM Part number: ERROR CORRECT VJ140600 (LENS,VF(ASSY)) VJ138100 (LENS,VF(ASSY)) Reference: Relation between the model and finder C-2020Z C-2040Z C-3030Z C-3040Z VJ138100 > > VJ140600 > VJ209600 > OLYM
TID-C3040Z-E003.pdfTECHNICAL INFORMATION NO. TID-C3040Z-003 DATE Nov.21.2001 SUBJECT: Version up of Firmware Product name: C-3040ZOOM The latest firmware: OLD VERSION V354-76 V354u-76 V354p-75 NEW VERSION V354-77 V354u-77 V354p-76 NTSC(GUI:JAPANESE) NTSC(GUI:ENGLISH) PAL Please refer to repair article for a procedure of rewriting firmware. Change contents (Reason): It changed in order to carry out "SDK" for dentistry photography. The command that can set up a "custom clear setting" from PC was added. This is not related to ordinary users. Change classification: Running change Version up procedure: 1. The binary data of the latest firmware is changed with "firmware.bin" and into smart media. But format smart media into C-3040Zoom and make directory "firmware" copy from binary data. (Make F/W card) 2. Insert the F/W card for C-3040Zoom and turn on the camera at play mode. 3. TFT-LCD was showed F/W version and inquire of rewriting of F/W. Then select "YES" (Character is changed green) and after pressing

Download restrictions information:
 LimitDownloaded
Day5000
Month50006
Wrong count ?
* daily quota restriction will be cleared in 17h 34m


Download >> To download the file, please, click here ! << Download
eServiceInfo Context Help
Attention! This manual is multipart. Download all, before decompressing


Did You find this Service Manual useful? Share it:



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


 Links -  Info / Contacts -  Forum -   Last SM download : technisat digibox

script execution: 0.03 s