Information about the files in archive: |
Decompress result: | OK |
Extracted files: | 12 |
File name | | Text |
1_Cover Page_v1.pdf | | REPAIR MANUAL
C3040ZOOM
- INDEX -
SERVER_DIS
Service Group, Technical Service Department OLYMPUS OPTICAL CO.,LTD
Ver.1 |
B_Disassembly and Assembly Procedure_v1.pdf | | B. DISASSEMBLY AND ASSEMBLY PROCEDURE
C-3040 Zoom
B. DISASSEMBLY AND ASSEMBLY PROCEDURE
REMOVAL OF CABINET TOP ASSEMBLY, CABINET FRONT ASSEMBLY AND CABINET BACK ASSEMBLY ... B-2 [2] REMOVAL OF LENS VF AND FLEXIBLE PWB ... B-3 [3] REMOVAL OF LENS ASSEMBLY AND CA1 BOARD ... B-4 [4] REMOVAL OF SY1 BOARD,CA2 BOARD AND ST1 BOARD ... B-4 [5] BOARD LOCATION ... B-5 [1]
SERVER_DIS
B-1
Ver.1
B. DISASSEMBLY AND ASSEMBLY PROCEDURE
C-3040 Zoom
[1]REMOVAL OF ABINET TOP ASSEMBLY,CABINET FRON TASSEMBLY AND CABINET BACK ASSEMBLY Disassembly perform as follows (1, 2...23) and assembly perform by reversing the disassembly steps (23, 22...1). Be sure to discharge the main capacitor in procedure 11, then continueu to disassembling.
!
Beware of electric shock
Danger of el |
C_Adjustment Method_V1R3.pdf | | C. ADJUSTMENT METHOD
C-3040 Zoom
C. ADJUSTMENT METHOD
[1] TABLE FOR SERVICING TOOLS ... C-2 [2] EQUIPMENT ... C-2 [3] ADJUSTMENT ITEMS AND ORDER ... C-2 [4] SETUP ... C-2 [5] CONNECTING THE CAMERA TO THE COMPUTER ... C-3 [6] USB STORAGE INFORMATION REGISTRATION ... C-4 [7] ADJUST SPECIFICATIONS ... C-5 1. IC501 OSCILLATION FREQUENCY ADJUSTMENT ... C-5 2. 5.1 V (A) VOLTAGE ADJUSTMENT ... |
D_Repair Procedure_v1.pdf | | D. REPAIR PROCEDURE
C-3040 Zoom
D. REPAIR PROCEDURE
[1] TROUBLESHOOTING GUIDE ... D-2 POWER LOSS INOPERATIVE ... D-2 TAKING INOPERATIVE ... D-2 NO PICTURE ... D-2
SERVER_DIS
D-1
Ver.1
D. REPAIR PROCEDURE
C-3040 Zoom
[1] TROUBLESHOOTING GUIDE
POWER LOSS INOPERTIVE
IC301-91 (SCAN IN 0) PULSE INPUT
TAKING INOPERATIVE
PUSH SHUTTER BUTTON
NO
CHECK PFC include POWER SW, CN301, R3021
YES
IC302-7 (UNREG)
LOW
CHECK ST1, CA2
IC301-3, 7 (SCAN IN 3) PULSE INPUT
NO
CHECK PFC include POWER SW, CN301, R3023, R3024
HIGH
IC301-81 (VDD)
YES LOW
CHECK IC302 CN301-7, 8 (P ON, P(A) ON)
LOW
CHECK IC301, Q3005, Q3006, ST1
HIGH
IC301-84 (RESET)
|
E_Notice of Modification_V1R6.pdf | | C-3040ZOOM
E. NOTICE OF MODIFICATION
1. Correction of parts number ...E-2 2. Correction of parts number and description...E-3
E-1
Ver.1/Rev.6
E. NOTICE OF MODIFICATION
C-3040ZOOM
SUBJECT
Correction of parts number
2002.12.6
[Content] Corrected the following parts number because of error in writing
old GEAR CAM GEAR SHAFT VE083900 VE083955
new VE083901 VE083900
Rev.5 SERVER_DIS E-2 Ver.1
C-3040ZOOM
SUBJECT
Correction of parts number and description
2003.01.09
[Content] Corrected the following parts and description number because of error in writing
old VJ1877000 4Z FRAME #
new VJ187900 K-FPC#
Rev.6
Ver.1
E-3 |
Maintenance History_V1R2.pdf | | Maintenance History
MODEL: C-3040 Zoom
No. Date of issued 2000.12.11 2000.01.10 Page Detail 1/1
Ver.1 Rev.1
1 set EPD:2/2 PL:2,6
Initial Revised Revised Revised Part number correction (VC153900VE297300) VE121500("NEW" Elimination),Serial number seal addition Part number correction (VJ140600VJ138100)
Rev.2
2001.07.19
EPD:2/2 PL:3
SERVER_DIS
Technical Service Group, Quality Assurance Department OLYMPUS OPTICAL CO.,LTD |
Maintenance History_V1R6.pdf | | Maintenance History
MODEL: C-3040 Zoom
No. Date of issued 2000.12.11 2000.01.10 Page Detail 1/1
Ver.1 Rev.1
1 set EPD:2/2 PL:2,6
Initial Revised Revised Revised Part number correction (VC153900VE297300) VE121500("NEW" Elimination),Serial number seal addition Part number correction (VJ140600VJ138100)
Rev.2
2001.07.19
EPD:2/2 PL:3
Rev.3
2002.10.07
C-1,12,13,14 EPD:3/3 PL:ALL(6)
Addition
Make the check procedure of Lens unit Add new parts of Lens unit
Revised Revised Revised Corrected misprints
Rev.4 Rev.5
2002.10.17 2002.12.06
EPD:1/3,2/3 E-1,2 EPD:2/3,3/3 PL:2/6
Correction of parts number
Rev.6
2003.01.09
E-1,3 EPD: 3/3 PL:3/6
Revised
Correction of parts number and description
SERVER_DIS
Technical Section, Support Service Department OLYMPUS OPTICAL CO., LTD |
Parts List C-3040Zoom_V1R6.pdf | | A B C D
Cabinet 1
VE208600 VC264500
VC266200
VE210000
1 VC264500 VC264500 VE210200
VE209200 VE087400
VE209800 VC266300
VE087800 VC130600 VC114700
VE202200 VC264500
VC129900
VE089300 |
T134-001.PDF | | No. T134 - 001 27th Apr. 01
TECHNICAL INFORMATION
OE/CPI-TSD
C-3040ZOOM New Firmware (v354p-75)
Description
Changing the firmware of C-3040ZOOM because of improving software PAL : v354p-75 NTSC(GUI:English) : v354u-76 NTSC(GUI:Japanese) : v354-76
Contents
The following contents are modified by new software. 1. It hangs-up, if folder name is "DCIM".
Countermeasure
Install the above new firmware in all C-3040ZOOM that has old firmware version.
Version Up Procedure (From Smartmedia Card)
1. 2. 3. 4. 5. 6. 7. Prepare Smartmedia Card for new firmware Make "Firmware" folder in the Smartmedia Card Put new firmware as file name "firmware.bin" in "Firmware" folder. Note! : The file name has to be "firmware.bin", not "v354p-75". Insert the Smartmedia Card in C-3040ZOOM. Select "Play" mode with mode dial. Power ON C-3040ZOOM The current F/W version is indicated on TFT. Select "YES" and Press "OK" button. F/W rewriting is started automatically. It takes about 2 minutes. Note! : Don't touch an |
T134-002.PDF | | No. T134 - 002 30th Apr. 01
TECHNICAL INFORMATION
OE/CPI-TSD
Countermeasure for Record Error when "Red-Eye Reduction Flash" Mode is being used
Model
C-3000ZOOM / C-3030ZOOM / C-3040ZOOM / C-2040ZOOM
Phenomenon
Record error occurs when recording a picture which was taken with "Red-Eye Reduction Flash" mode, and it hangs-up. (This problem occurs seldom.)
Cause
Noise comes from a "CABINET TOP COVER" when flash is fired.
Countermeasure
Attach a Spacer Holder, if customer points out this problem. Please refer to the following picture.
VC157400 SPACER HOLDER
Spare parts number and name
VC157400 : SPACER HOLDER
OLYMPUS OPTICAL CO. (EUROPA) GMBH TECHNICAL SUPPORT DEPARTMENT CONSUMER PRODUCTS INTERNATIONAL
1/1 |
TID-C3040Z-E002.PDF | | TECHNICAL INFORMATION
NO. TID-C3040Z-E002
DATE July/26/2001
SUBJECT: Matter of the part number change (finder)
Content:
There was an error in the part number (finder) of the following model.
The part number is changed.
Product name:
C-3040ZOOM
Part number:
ERROR CORRECT
VJ140600 (LENS,VF(ASSY)) VJ138100 (LENS,VF(ASSY))
Reference:
Relation between the model and finder
C-2020Z C-2040Z C-3030Z C-3040Z
VJ138100 ·> ·>
VJ140600 ·>
VJ209600 ·>
OLYMPUS OPTICAL CO.,LTD TOKYO |
TID-C3040Z-E003.pdf | | TECHNICAL INFORMATION
NO. TID-C3040Z-003 DATE Nov.21.2001
SUBJECT: Version up of Firmware
Product name: C-3040ZOOM The latest firmware: OLD VERSION V354-76 V354u-76 V354p-75 NEW VERSION V354-77 V354u-77 V354p-76
NTSC(GUI:JAPANESE) NTSC(GUI:ENGLISH) PAL
Please refer to repair article for a procedure of rewriting firmware. Change contents (Reason): It changed in order to carry out "SDK" for dentistry photography. The command that can set up a "custom clear setting" from PC was added. This is not related to ordinary users. Change classification: Running change Version up procedure: 1. The binary data of the latest firmware is changed with "firmware.bin" and into smart media. But format smart media into C-3040Zoom and make directory "firmware" copy from binary data. (Make F/W card) 2. Insert the F/W card for C-3040Zoom and turn on the camera at play mode. 3. TFT-LCD was showed F/W version and inquire of rewriting of F/W. Then select "YES" (Character is changed green) and after pressing |